|
|
STERLING CE PHOSPHORAMIDITES
Glen Research CE (ß-cyanoethyl) Phosphoramidites are
produced and packaged to ensure the highest performance on DNA synthesizers.
Every Glen Research product is accompanied by a Certificate of Analysis
and HPLC trace, showing the results of our QC testing. Every Glen Research
monomer vial is specially cleaned to eliminate particulate contamination.
| 10-1000-B2 |
0.25g |
12.50 |
| |
10-1000-B5 |
0.5g |
25.00 |
| |
10-1000-1B |
1.0g |
50.00 |
| 10-1010-B2 |
0.25g |
12.50 |
| |
10-1010-B5 |
0.5g |
25.00 |
| |
10-1010-1B |
1.0g |
50.00 |
| 10-1015-B2 |
0.25g |
12.50 |
| |
10-1015-B5 |
0.5g |
25.00 |
| |
10-1015-1B |
1.0g |
50.00 |
| 10-1020-B2 |
0.25g |
12.50 |
| |
10-1020-B5 |
0.5g |
25.00 |
| |
10-1020-1B |
1.0g |
50.00 |
| 10-1029-B2 |
0.25g |
12.50 |
| |
10-1029-B5 |
0.5g |
25.00 |
| |
10-1029-1B |
1.0g |
50.00 |
| 10-1030-B2 |
0.25g |
12.50 |
| |
10-1030-B5 |
0.5g |
25.00 |
|
10-1030-1B |
1.0g |
50.00 |
|
QUALITY ASSURANCE
Every batch of these CE Phosphoramidites is tested as
follows
- HPLC
a) Identity is confirmed by comparison with a reference sample.
b) Purity is determined by HPLC to be ≥98.0%.
- TLC
Purity is verified by TLC.
- 31P NMR
Purity is determined by 31P NMR to be ≥98%.
- Coupling Test
Coupling efficiency is determined to be ≥99%.
- Solution Test
A 0.1M solution is determined to be clear and free of particulate contamination.
- Loss on Drying
Volatile contaminants are determined to be ≤2%.
|
STERLING SOLVENTS/REAGENTS
All solvents and reagents are prepared to our exacting
specifications to ensure the highest synthesis efficiency and are passed
through a 0.2 micron filter during packaging to eliminate particulate
contamination. Glen Research uses freshly sublimed 1H-tetrazole for premium
performance on DNA synthesizers.
| 30-3100-52 |
200mL |
100.00 |
| 40-4050-45 |
60mL |
12.00 |
| |
40-4050-50 |
100mL |
16.00 |
| 40-4010-52 |
200mL |
30.00 |
| 40-4120-52 |
200mL |
30.00 |
| 40-4220-52 |
200mL |
40.00 |
| 40-4430-52 |
200mL |
|
| 40-4330-52 |
200mL |
30.00 |
| 40-4140-57 |
450mL |
36.00 |
|
ABBREVIATIONS
Ac2O = Acetic Anhydride
CE = Cyanoethyl
CPG = Controlled Pore Glass
DCM = Dichloromethane I2 = Iodine
MeIm = 1-Methylimidazole
THF = Tetrahydrofuran
TCA = Trichloroacetic Acid
|
STERLING SUPPORTS
Oligo 1000 instruments use unique columns available
from Beckman Instruments and we recommend these columns. However, Applied
Biosystems columns, see Pages 7-8, can be used on Oligo 1000 instruments
with the use of an adapter available from Beckman, Part Number 607824.
|
|